ASTM E1949 Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1949 Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
- 19
- CENELEC EN 62047-8 Semiconductor devices - Micro-electromechanical devices - Part 8: Strip bending test method for tensile property measurement of thin films
- 31
- CENELEC EN 62047-8 Semiconductor devices - Micro-electromechanical devices - Part 8: Strip bending test method for tensile property measurement of thin films
- 31.080
- CENELEC EN 62047-8 Semiconductor devices - Micro-electromechanical devices - Part 8: Strip bending test method for tensile property measurement of thin films
- CENELEC EN 62047-21 Semiconductor devices - Micro-electromechanical devices - Part 21: Test method for Poisson's ratio of thin film MEMS materials
- ASTM E132 Standard Test Method for Poisson’s Ratio at Room Temperature
- ASTM E1012 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
- ASTM E1237 Standard Guide for Installing Bonded Resistance Strain Gages
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
N E1949
Annotation
This test method covers a uniform procedure for the determination of strain gage fatigue life at ambient temperature. A suggested testing equipment design is included.
This test method does not apply to force transducers or extensometers that use bonded resistance strain gages as sensing elements.
Strain gages are part of a complex system that includes structure, adhesive, gage, lead wires, instrumentation, and (often) environmental protection. As a result, many things affect the performance of strain gages, including user technique. A further complication is that strain gages, once installed, normally cannot be reinstalled in another location. Therefore, it is not possible to calibrate individual strain gages; performance characteristics are normally presented on a statistical basis.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.
Автоматический перевод:
Стандартный метод испытаний для жизни усталости температуры окружающей среды металлических связанных тензодатчиков сопротивления