ASTM E215 Standard Practice for Standardizing Equipment for Electromagnetic Testing of Seamless Aluminum-Alloy Tube
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM A450/A450M Standard Specification for General Requirements for Carbon and Low Alloy Steel Tubes
- ASTM A822/A822M Standard Specification for Seamless Cold-Drawn Carbon Steel Tubing for Hydraulic System Service
- 23
- ASTM A822/A822M Standard Specification for Seamless Cold-Drawn Carbon Steel Tubing for Hydraulic System Service
- 23.100
- IEC 60079-10-2 Explosive atmospheres – Part 10-2: Classification of areas – Combustible dust atmospheres - Edition 1.0
- ISO 10439 Petroleum, Chemical and Gas Service Industries - Centrifugal Compressors - First Edition
- ISO 10439 Petroleum, Chemical and Gas Service Industries - Centrifugal Compressors - First Edition
- ASTM A522/A522M Standard Specification for Forged or Rolled 8 and 9% Nickel Alloy Steel Flanges, Fittings, Valves, and Parts for Low-Temperature Service
- ASME B31.5 Refrigeration Piping and Heat Transfer Components
- ASTM A450/A450M Standard Specification for General Requirements for Carbon and Low Alloy Steel Tubes
- ASTM E426 Standard Practice for Electromagnetic (Eddy-Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Standardizing Equipment for Electromagnetic Testing of Seamless Aluminum-Alloy Tube
N E215
Annotation
This practice2 is for standardizing eddy current equipment employed in the examination of seamless aluminum-alloy tube. Artificial discontinuities consisting of flat-bottomed or through holes, or both, are employed as the means of standardizing the eddy current system. General requirements for eddy current examination procedures are included
Procedures for fabrication of reference standards are given in Appendixes X1.1 and X2.1
This practice is intended for the examination of tubular products having nominal diameters up to 4 in. [101.6 mm] and wall thicknesses up to the standard depth of penetration (SDP) of eddy currents for the particular alloy (conductivity) being examined and the examination frequency being used
NOTE 1—This practice may also be used for larger diameters or heavier walls up to the effective depth of penetration (EDP) of eddy currents as long as adequate resolution is obtained and as specified by the using party or parties
This practice does not establish acceptance criteria. They must be established by the using party or parties
The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard
This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use
*A Summary of Changes section appears at the end of this standard