ASTM E426 Standard Practice for Electromagnetic (Eddy-Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM A450/A450M Standard Specification for General Requirements for Carbon and Low Alloy Steel Tubes
- ASTM A822/A822M Standard Specification for Seamless Cold-Drawn Carbon Steel Tubing for Hydraulic System Service
- 23
- IEC 60079-10-2 Explosive atmospheres – Part 10-2: Classification of areas – Combustible dust atmospheres - Edition 1.0
- ISO 10439 Petroleum, Chemical and Gas Service Industries - Centrifugal Compressors - First Edition
- ASTM A522/A522M Standard Specification for Forged or Rolled 8 and 9% Nickel Alloy Steel Flanges, Fittings, Valves, and Parts for Low-Temperature Service
- ASME B31.5 Refrigeration Piping and Heat Transfer Components
- ASTM A450/A450M Standard Specification for General Requirements for Carbon and Low Alloy Steel Tubes
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Electromagnetic (Eddy-Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys
N E426
Annotation
This practice2 covers procedures for eddy-current examination of seamless and welded tubular products made of relatively low conductivity materials such as titanium, stainless steel, and similar alloys, such as nickel alloys. Austenitic chromium-nickel stainless steels, which are generally considered to be nonmagnetic, are specifically covered as distinguished from the martensitic and ferritic straight chromium stainless steels which are magnetic.
This practice is intended as a guide for eddy-current examination of both seamless and welded tubular products using either an encircling coil or a probe-coil technique. Coils and probes are available that can be used inside the tubular product; however, their use is not specifically covered in this document. This type of examination is usually employed only to examine tubing which has been installed such as in a heat exchanger.
This practice covers the examination of tubular products ranging in diameter from 0.125 to 5 in. (3.2 to 127.0 mm) and wall thicknesses from 0.005 to 0.250 in. (0.127 to 6.4 mm).
For examination of aluminum alloy tubular products, see standard Practice E215.
Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.