ASTM A268/A268M Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM F2916 Standard Practice for Environmental Impact Analysis of Commercial Food Service Equipment
- 97
- ASTM F2916 Standard Practice for Environmental Impact Analysis of Commercial Food Service Equipment
- 97.040
- ASTM F2916 Standard Practice for Environmental Impact Analysis of Commercial Food Service Equipment
- 97.040.01
- ASTM F1521 Standard Test Methods for Performance of Range Tops
- ASTM F2521 Standard Specification for Heavy-Duty Ranges, Gas and Electric
- ASTM F1275 Standard Test Method for Performance of Griddles
- ASTM F2875 Standard Guide for Laboratory Requirements Necessary to Test Commercial Cooking and Warming Appliances to ASTM Test Methods
- ASTM F1786 Standard Test Method for Performance of Braising Pans
- ASTM F1047 Standard Specification for Frying and Braising Pans, Tilting Type
- Картотека зарубежных и международных стандартов
ASTM International
Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service
N A268/A268M
Annotation
This specification2 covers a number of grades of nominal-wall-thickness, stainless steel tubing for general corrosion-resisting and high-temperature service. Most of these grades are commonly known as the "straight-chromium" types and are characterized by being ferromagnetic. Two of these grades, TP410 and UNS S 41500 (Table 1), are amenable to hardening by heat treatment, and the high-chromium, ferritic alloys are sensitive to notch-brittleness on slow cooling to ordinary temperatures. These features should be recognized in the use of these materials. Grade TP439 is used primarily for hot-water tank service and does not require post-weld heat treatment to prevent attack of the heat affected zone.
An optional supplementary requirement is provided, and when desired, shall be so stated in the order.
The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the "M" designation of this specification is specified in the order.
*A Summary of Changes section appears at the end of this standard.
2 For ASME Boiler and Pressure Vessel Code applications see related Specification SA-268 in Section II of that Code.