CENELEC EN 60352-2 Solderless Connections Part 2: Crimped Connections - General Requirements, Test Methods and Practical Guidance - Incorporates Amendment A1: 2013
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60918 PVC Insulated Ribbon Cable with a Pitch of 1,27 mm Suitable for Insulation Displacement Termination - Edition 1.0; Includes Amendment 1: 06/1992
- 29
- IEC 60918 PVC Insulated Ribbon Cable with a Pitch of 1,27 mm Suitable for Insulation Displacement Termination - Edition 1.0; Includes Amendment 1: 06/1992
- 29.060
- IEC 60918 PVC Insulated Ribbon Cable with a Pitch of 1,27 mm Suitable for Insulation Displacement Termination - Edition 1.0; Includes Amendment 1: 06/1992
- 29.060.20
- IEC 60918 PVC Insulated Ribbon Cable with a Pitch of 1,27 mm Suitable for Insulation Displacement Termination - Edition 1.0; Includes Amendment 1: 06/1992
- CEI EN 60947-1 Low-voltage switchgear and controlgear - Part 1: General rules - Fifth Edition
- IEC 60344 CORR 1 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires – Application guide - Edition 3.0
- BSI BS EN 60999-1 Connecting Devices - Electrical Copper Conductors - Saftey Requirements for Screw-Type and Screwless-Type Clamping Units - Part 1:General Requirements and Particular Requirements for Clamping Units for Conductors from 0,2 mm2 up to 35 mm2 (Included)
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60352-3 Solderless Connections Part 3: Solderless Accessible Insulation Displacement Connections - General Requirements, Test Methods and Practical Guidance
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60999-1 Connecting Devices - Electrical Copper Conductors - Saftey Requirements for Screw-Type and Screwless-Type Clamping Units - Part 1:General Requirements and Particular Requirements for Clamping Units for Conductors from 0,2 mm2 up to 35 mm2 (Included)
- IEC 60344 CORR 1 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires – Application guide - Edition 3.0
- IEC 60344 CORR 1 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires – Application guide - Edition 3.0
- BSI BS EN 60999-1 Connecting Devices - Electrical Copper Conductors - Saftey Requirements for Screw-Type and Screwless-Type Clamping Units - Part 1:General Requirements and Particular Requirements for Clamping Units for Conductors from 0,2 mm2 up to 35 mm2 (Included)
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60352-3 Solderless Connections Part 3: Solderless Accessible Insulation Displacement Connections - General Requirements, Test Methods and Practical Guidance
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60999-1 Connecting Devices - Electrical Copper Conductors - Saftey Requirements for Screw-Type and Screwless-Type Clamping Units - Part 1:General Requirements and Particular Requirements for Clamping Units for Conductors from 0,2 mm2 up to 35 mm2 (Included)
- BSI BS EN 60999-1 Connecting Devices - Electrical Copper Conductors - Saftey Requirements for Screw-Type and Screwless-Type Clamping Units - Part 1:General Requirements and Particular Requirements for Clamping Units for Conductors from 0,2 mm2 up to 35 mm2 (Included)
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60352-3 Solderless Connections Part 3: Solderless Accessible Insulation Displacement Connections - General Requirements, Test Methods and Practical Guidance
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 50521 + A1 Connectors for photovoltaic systems - Safety requirements and tests - AMD: September 30, 2012
- BSI BS EN 60352-3 Solderless Connections Part 3: Solderless Accessible Insulation Displacement Connections - General Requirements, Test Methods and Practical Guidance
- BSI BS EN 60352-3 Solderless Connections Part 3: Solderless Accessible Insulation Displacement Connections - General Requirements, Test Methods and Practical Guidance
- BSI BS EN 60352-4 Solderless Connections Part 4: Solderless Non- Accessible Displacement Connections - General Requirements, Test Methods and Practical Guidance - AMD 13095: November 16, 2001
- IEC 60189-3 Low-frequency cables and wires with PVC insulation and PVC sheath – Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples - Edition 4.0
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Solderless Connections Part 2: Crimped Connections - General Requirements, Test Methods and Practical Guidance - Incorporates Amendment A1: 2013
N EN 60352-2
Annotation
Scope and object
This part of IEC 60352 is applicable to solderless crimped connections made with stranded wires of 0,05 mm2 to 10 mm2 c ross-section or solid wires of 0,25 mm to 3,6 mm diameter and appropriately designed uninsulated or pre-insulated crimp barrels for use in telecommunication equipment and in electronic devices employing similar techniques.
Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically s table connections under prescribed environmental conditions.
NOTE This part of IEC 60352 is not intended to be applicable to crimping of coaxial cables.
The object o f this part o f IEC 6 0352 is to determine the suitability of solderless crimped connections under specified mechanical, electrical and atmospheric conditions and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture.
Автоматический перевод:
Часть 2 соединений без пайки: соединения, которым помешали - общие требования, методы тестирования и практическое руководство - включают поправку A1: 2013