Annotation

 

This part of IEC 60079 specifies the general requirements for construction, testing and marking of electrical equipment and Ex components intended for use in explosive atmospheres.

Unless modified by one of the standards supplementing this standard, electrical equipment complying with this standard is intended for use in hazardous areas in which explosive atmospheres exist under normal atmospheric conditions of

• temperature –20 °C to +60 °C;

• pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and

• air with normal oxygen content, typically 21 % v/v.

The application of electrical equipment in atmospheric conditions outside this range requires special consideration and may require additional assessment and testing.

NOTE 1 Although the normal atmospheric conditions above give a temperature range for the atmosphere of -20°C to +60°C, the normal ambient temperature range for the equipment is -20°C to +40°C, unless otherwise specified and marked. See 5.1.1.

NOTE 2 In designing equipment for operation in explosive atmospheres under conditions other than the atmospheric conditions given above, this standard may be used for guidance. However, additional testing related specifically to the intended conditions of use is recommended. This is particularly important when the types of protection ‘flameproof enclosure "d"' (IEC 60079-1) and ‘intrinsic safety "i"' (IEC 60079-11 or IEC 61241-11) are applied.