API BULL 2517 Bulletin on Evaporation Loss From Floating-Roof Tanks
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60079-32-2 Explosive atmospheres – Part 32-2: Electrostatics hazards – Tests - Edition 1.0
- BSI PD CEN/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- IEC 60984 Live working – Electrical insulating sleeves - Edition 2.0
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- IEC 60984 Live working – Electrical insulating sleeves - Edition 2.0
- BSI PD CEN/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- BSI PD CEN/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- IEC 60984 Live working – Electrical insulating sleeves - Edition 2.0
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- IEC 60984 Live working – Electrical insulating sleeves - Edition 2.0
- IEC 60984 Live working – Electrical insulating sleeves - Edition 2.0
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-8 Non-electrical equipment for potentially explosive atmospheres Part 8: Protection by liquid immersion ?k?
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- CEN EN 13478 Safety of machinery - Fire prevention and protection - Incorporates Amendment A1: 2008
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 14591-1 Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structure - CORR 16252: April 28, 2006
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13478 + A1 Safety of machinery - Fire prevention and protection - AMD: July 31, 2009
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- BSI BS EN 13463-5 Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by constructional safety 'c' - CORR: March 31, 2012
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 13463-6 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source ?b?
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- ISO 16852 CORR 2 Flame arresters — Performance requirements, test methods and limits for use TECHNICAL CORRIGENDUM 2 - First Edition
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- DIN EN 1012-3 Compressors and vacuum pumps - Safety requirements - Part 3: Process compressors
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- CEN EN ISO 14122-2 Safety of machinery - Permanent means of access to machinery - Part 2: Working platforms and walkways - Incorporates Amendment A1: 2010
- CEN EN 14015 Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above
- API MPMS 19.3 PART B Manual of Petroleum Measurement Standards Chapter 19.3-Evaporative Loss Measurement - Part B-Air Concentration Test Method-Rim-Seal Loss Factors for Floating-Roof Tanks - FIRST EDITION
- IEC 60079-32-2 Explosive atmospheres – Part 32-2: Electrostatics hazards – Tests - Edition 1.0
- Картотека зарубежных и международных стандартов
American Petroleum Institute
Bulletin on Evaporation Loss From Floating-Roof Tanks
N BULL 2517
Annotation
INTRODUCTION
The American Petroleum Institute sponsored a symposium on evaporation loss * at the Thirty-second Annual Meeting in 1952. The symposium papers presented average figures for standing-storage loss from floating-roof tanks expressed as barrels per foot of diameter per year per pound of true vapor pressure. Wide variation in the data was noted and further effort on correlating test results was recommended. Losses from butt-welded tanks with close-fitting seals also required additional consideration.
The API Evaporation Loss Committee, in 1957, collected from the petroleum industry both new and previously obtained data on evaporation loss from floating roof tanks. An intensive study was made of these data. As a result of this study, the effect of an additional variable, wind velocity, was determined and the earlier variables were defined more precisely resulting in a significant reduction in the spread of data for the various types of floating-roof tanks. This bulletin presents the resultant correlations for use in estimating evaporation loss.
To supplement the general description of equipment covered in API Bulletin 2513: Evaporation Loss in the Petroleum industry-Causes and Control, information is presented herein which deals with the vital seal portion of the floating roof. In addition to the metallic-shoe type of seal, the nonmetallic seal is discussed and a comparison is made of the features of each.
A guide to the selection, maintenance, and replacement of the floating-roof seal-based on manufacturers' publications, users' experience, and tests-is included in this bulletin.
* "Symposium on Evaporation Loss," Proc. API 32 [I] 213-81 (1952).