UL 1640 UL Standard for Portable Power-Distribution Equipment - Fourth Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- UL 1682 UL Standard for Safety Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type - Fourth Edition; Reprint with revisions through and including February 07, 2014
- CSA CAN/CSA-C22.2 NO. 60320-1-11 Appliance Couplers for Household and Similar General Purposes — Part 1: General Requirements - First Edition
- 29
- IEC 60335-2-3 AMD 1 AMENDMENT 1 Household and similar electrical appliances – Safety – Part 2-3: Particular requirements for electric irons - Edition 6.1; Consolidated Reprint
- IEC 60245-3 AMD 2 AMENDMENT 2 Rubber insulated cables – Rated voltages up to and including 450/750 V – Part 3: Heat resistant silicone insulated cables - Edition 2.0
- CSA CAN/CSA-C22.2 NO. 60335-1:11 Safety of Household and Similar Appliances — Part 1: General Requirements - First Edition
- CSA CAN/CSA-C22.2 NO. 60320-1-11 Appliance Couplers for Household and Similar General Purposes - Part 1: General Requirements - First Edition
- UL 498 UL Standard for Safety Attachment Plugs and Receptacles - Fifteenth Edition; Reprint with Revisions Through and Including July 7, 2016
- Картотека зарубежных и международных стандартов
Underwriters’ Laboratories
Standard for Portable Power-Distribution Equipment - Fourth Edition
N 1640
Annotation
These requirements cover portable power-distribution equipment rated 600 volts or less and 1600 amperes maximum. They are intended for either single- or multi-phase supply and are intended to distribute power in accordance with the National Electrical Code, NFPA 70 (NEC).
These requirements cover portable power-distribution equipment intended for use in the following locations:
a) Carnivals, circuses, fairs, and similar locations in accordance with Article 525 of the NEC;
b) Exhibition halls in accordance with Article 518 of the NEC;
c) Motion picture and television studios and similar locations in accordance with Article 530 of the NEC;
d) Theaters, audience areas of motion-picture and television studios, and similar locations in accordance with Article 520 of the NEC; and
e) Temporary installations at construction sites in accordance with Article 590 of the NEC.
These requirements do not cover portable power-distribution equipment:
a) Intended to be mounted above or adjacent to the lighting unit it supplies. These devices are covered by the Standard for Stage and Studio Luminaires and Connector Strips, UL 1573.
b) Intended to be connected to the load side of branch circuits, such as:
1) Relocatable power taps. These devices are covered by the Standard for Relocatable Power Taps, UL 1363;
2) Cord sets. These devices are covered by the Standard for Cord Sets and Power- Supply Cords, UL 817;