ASTM E1700 Standard Classification for Serviceability of an Office Facility for Structure and Building Envelope
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1700 Standard Classification for Serviceability of an Office Facility for Structure and Building Envelope
- 35
- ASTM E2132 Standard Practice for Inventory Verification: Electronic and Physical Inventory of Assets
- 13
- ASTM E2132 Standard Practice for Inventory Verification: Electronic and Physical Inventory of Assets
- 13.120
- ASTM E2132 Standard Practice for Inventory Verification: Electronic and Physical Inventory of Assets
- ASTM E2135 REV A Standard Terminology for Property and Asset Management
- ASTM E2812 Standard Practice for Uniform Data Management in Asset Management Records Systems
- ASTM E3035 Standard Classification for Facility Asset Component Tracking System (FACTS)
- ASTM E2166 Standard Practice for Organizing and Managing Building Data
- ASTM E1765 Standard Practice for Applying Analytical Hierarchy Process (AHP) to Multiattribute Decision Analysis of Investments Related to Projects, Products, and Processes
- Картотека зарубежных и международных стандартов
ASTM International
Standard Classification for Serviceability of an Office Facility for Structure and Building Envelope
N E1700
Annotation
This classification covers matched sets of scales (see Figs. 1-24) for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for structure and building envelope
Within that aspect of serviceability, each matched set of scales (see Figs. 1-24) is for classifying one topic of serviceability. Each topic is typically broken down into two more demand functions and supply features. Each paragraph in an Occupant Requirement Scale summarizes one level of serviceability on that function, which occupants might require. The matching entry in the Facility Rating Scale is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability
The entries in the Facility Rating Scale (see Figs. 1-24) are indicative and not comprehensive. They are for quick scanning, to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group, over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing
This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared
This classification indicates what would cause a facility to be rated at a certain level of serviceability, but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1679. The scales in Figs. 1-24 are complimentary to and compatible with Practice E1679. Each requires the other