ASTM F2732 Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM F2370 Standard Test Method for Measuring the Evaporative Resistance of Clothing Using a Sweating Manikin
- ASTM F2732 Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing
- 61
- JSA JIS C 8105-1 Luminaires - Part 1: General requirements for safety
- 13
- JSA JIS C 9335-2-17 Household and similar electrical appliances - Safety - Part 2-17 : Particular requirements for blankets, pads and similar flexible heating appliances
- ISO 3758 Textiles - Care labelling code using symbols - Third Edition
- CEN EN 13537 Requirements for sleeping bags - Remains Current
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing
N F2732
Annotation
This standard practice covers the determination of the temperature rating of cold weather protective clothing ensembles. It involves measuring the thermal resistance (insulation) value of a clothing ensemble with a heated manikin in accordance with Test Method F1291 and using a heat loss model to predict the lowest environmental temperature for comfort.
The predictive model used in this standard estimates the evaporative heat loss from a person wearing cold weather clothing as opposed to measuring the evaporative resistance on a sweating manikin. If a person is active and gets overheated in a cold environment, he/she is usually able to adjust the garments in order to dissipate excess heat.
The temperature ratings estimated by this standard practice are guidelines for thermal comfort that are designed to protect people from hypothermia when wearing cold weather protective garments. However, localized cooling, discomfort, and even frostbite could still occur at extremely low temperatures because clothing insulation is not evenly distributed over the body surface. In addition, some body parts (for example, ears, fingers, toes) have a high surface area relative to their mass, and consequently lose heat at a faster rate than other parts of the body.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Автоматический перевод:



