CENELEC EN 45544-4 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 4: Guide for selection, installation, use and maintenance
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CEN EN 50270 Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
- 13
- 19
- 33
- BSI BS EN 50270 Electromagnetic Compatibility - Electrical Apparatus for the Detection and Measurement of Combustible Gases, Toxic Gases or Oxygen
- CENELEC EN 50545-1 Electrical apparatus for the detection and measurement of toxic and combustible gases in car parks and tunnels Part 1: General performance requirements and test methods for the detection and measurement of carbon monoxide and nitrogen oxides - Incorporates Amendment A1: 2016
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 4: Guide for selection, installation, use and maintenance
N EN 45544-4
Annotation
This European Standard gives guidance on the selection, installation, use and maintenance of electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours in workplace atmospheres. The primary purpose of such apparatus is to measure the concentration of a toxic gas or vapour in order to provide an exposure measurement and/or detection and warning of its presence.
This European Standard is applicable to apparatus whose primary purpose is to provide an indication, alarm and/or other output function to give a warning of the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective actions. It is applicable to apparatus in which the sensor automatically generates an electrical signal when gas is present.
This European Standard is not applicable, but may provide useful information, for apparatus
— used for the measurement of oxygen,
— used only in laboratories for analysis or measurement,
— used only for process measurement purposes,
— used in car parks or tunnels (fixed apparatus only),
— used in the domestic environment,
— used in environmental air pollution monitoring,
— used for the measurement of combustible gases and vapours related to the risk of explosion.