CENELEC EN 62387 Radiation protection instrumentation - Passive integrating dosimetry systems for individual, workplace and environmental monitoring of photon and beta radiation
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- 29
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- 29.260
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- 29.260.20
- BSI BS EN 60079-10-1 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
- CENELEC EN 60079-0 Explosive atmospheres - Part 0: Equipment - General requirements - Incorporates Amendment A11: 2013
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Radiation protection instrumentation - Passive integrating dosimetry systems for individual, workplace and environmental monitoring of photon and beta radiation
N EN 62387
Annotation
This standard applies to all kinds of passive dosimetry systems that are used for measuring – the personal dose equivalent Hp(10) (for whole body dosimetry),
– the personal dose equivalent Hp(3) (for eye lens dosimetry),
– the personal dose equivalent Hp(0,07) (for both whole body and extremity dosimetry),
– the ambient dose equivalent H*(10) (for environmental dosimetry), or
– the directional dose equivalent H ’(0,07) (for environmental dosimetry).
This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the prevailing dose quantity. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
NOTE 2 In this standard, “dose” means dose equivalent, unless otherwise stated.
NOTE 3 For Hp(10) and H*(10) no beta radiation is considered. Reasons: 1) Hp(10) and H*(10) are a conservative estimate for the effective dose which is not a suitable quantity for beta radiation. 2) No conversion coefficients are available in ICRU 56, ICRU 57 or ISO 6980-3.
NOTE 4 The maximum energy ranges are the energy limits within which type tests according to this standard are possible. The test methods concerning the design (Clause 8), the instruction manual (Clause 9), the software (Clause 10), environmental influences (Clause 13), electromagnetic influences (Clause 14), mechanical influences (Clause 15), and the documentation (Clause 16) are independent of the type of radiation Therefore they can also be applied to other dosimetry system, eg for neutrons, utilizing the corresponding type of a radiation for testing