ASTM D6214/D6214M Standard Test Method for Determining the Integrity of Field Seams Used in Joining Geomembranes by Chemical Fusion Methods
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7002 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
- 59
- ASTM D7002 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
- 59.080
- ASTM D7007 Standard Practices for Electrical Methods for Locating Leaks in Geomembranes Covered with Water or Earthen Materials
- ASTM D7007 Standard Practices for Electrical Methods for Locating Leaks in Geomembranes Covered with Water or Earthen Materials
- ASTM D6747 Standard Guide for Selection of Techniques for Electrical Leak Location of Leaks in Geomembranes
- ASTM D7700 Standard Guide for Selecting Test Methods for Geomembrane Seams
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Determining the Integrity of Field Seams Used in Joining Geomembranes by Chemical Fusion Methods
N D6214/D6214M
Annotation
This test method covers an accelerated, destructive test method for geomembranes in a geotechnical application.
This test is applicable to field fabricated geomembranes that are scrim reinforced or non reinforced.
This test method is applicable for field seaming processes that use a chemical fusion agent or bodied chemical fusion agent, as the seaming mechanism.
Subsequent decisions as to seam acceptance criteria are made according to the site-specific contract plans, specification and CQC/CQA documents.
The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
Hazardous Materials-Always consult the proper Material Safety Data Sheets for any Hazardous materials used for proper ventilation and protection. The use of the oven in this test method may accelerate fume production from the test specimen.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicable of regulatory limitations prior to use.