ASTM D6956 Standard Guide for Demonstrating and Assessing Whether a Chemical Analytical Measurement System Provides Analytical Results Consistent with Their Intended Use
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- ASTM D6250 Standard Practice for Derivation of Decision Point and Confidence Limit for Statistical Testing of Mean Concentration in Waste Management Decisions
- ASTM D5680 Standard Practice for Sampling Unconsolidated Solids in Drums or Similar Containers
- 13
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- ASTM D6250 Standard Practice for Derivation of Decision Point and Confidence Limit for Statistical Testing of Mean Concentration in Waste Management Decisions
- ASTM D5680 Standard Practice for Sampling Unconsolidated Solids in Drums or Similar Containers
- 13.030
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- ASTM D5680 Standard Practice for Sampling Unconsolidated Solids in Drums or Similar Containers
- ASTM D6051 Standard Guide for Composite Sampling and Field Subsampling for Environmental Waste Management Activities
- ASTM D6232 Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- ASTM D6250 Standard Practice for Derivation of Decision Point and Confidence Limit for Statistical Testing of Mean Concentration in Waste Management Decisions
- ASTM D7204 Standard Practice for Sampling Waste Streams on Conveyors
- Картотека зарубежных и международных стандартов
ASTM International
Standard Guide for Demonstrating and Assessing Whether a Chemical Analytical Measurement System Provides Analytical Results Consistent with Their Intended Use
N D6956
Annotation
This guide describes an approach for demonstrating the quality of analytical chemical measurement results from the application of a measurement system (that is, method or sequence of methods) to the analysis of environmental samples of soil, water, air, or waste. The purpose of such measurements can include demonstrating compliance with a regulatory limit, determining whether a site is contaminated above some specified level, or determining treatment process efficacy.
This guide describes a procedure that can be used to assess a measurement system used to generate analytical results for a specific purpose. Users and reviewers of the analytical results can determine, with a known level of confidence, if they meet the quality requirements and are suitable for the intended use.
This protocol does not address the general components of laboratory quality systems necessary to ensure the overall quality of laboratory operations. For such systems, the user is referred to International Standards Organization (ISO) Standard 17025 or the National Environmental Laboratory Accreditation Conference (NELAC) laboratory accreditation standards.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.