ASTM F3010 Standard Practice for Two-Component Resin Based Membrane-Forming Moisture Mitigation Systems for Use Under Resilient Floor Coverings
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM F1869 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride
- ASTM F1482 Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring
- 97
- ASTM F2873 Standard Practice for the Installation of Self-Leveling Underlayment and the Preparation of Surface to Receive Resilient Flooring
- ASTM F3009 Standard Specification for Polyolefin Composition Floor Tile
- ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Two-Component Resin Based Membrane-Forming Moisture Mitigation Systems for Use Under Resilient Floor Coverings
N F3010
Annotation
This practice covers the properties, application, and performance of a two-component resin based membraneforming moisture mitigation system to high moisture concrete substrates prior to the installation of resilient flooring.
This practice includes recommendations for the preparation of the concrete surface to receive a two-component resin based membrane-forming moisture mitigation system.
This practice does not supersede written instructions of the two-component resin based membrane-forming moisture mitigation system manufacturer, the resilient flooring manufacturer, underlayment manufacturer, the adhesive manufacturer, or other components of the finish flooring system, or combinations thereof. Users of this practice shall review manufacturer's technical data sheets and installation instructions for compatibility of system components.
The following membrane-forming or non membraneforming moisture mitigation systems are not included in the scope of this practice:
Moisture mitigation systems that chemically react with any constituent of the concrete to form a gel or crystalline substance within the concrete.
Penetrating, water- or solvent-based compounds that do not form a continuous membrane on the concrete surface.
Water-based membrane-forming moisture mitigation systems are not included in the scope of this document.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.