ISO/ASTM 51261 Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67.160
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67.160.10
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- ASTM E1958 Standard Guide for Sensory Claim Substantiation
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- ASTM E2164 Standard Test Method for Directional Difference Test
- ASTM E460 Standard Practice for Determining Effect of Packaging on Food and Beverage Products During Storage
- ASTM F1640 Standard Guide for Selection and Use of Packaging Materials for Foods to Be Irradiated
- ASTM F1355 Standard Guide for Irradiation of Fresh Agricultural Produce as a Phytosanitary Treatment
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing
N ISO/ASTM 51261
Annotation
This practice specifies the requirements for calibrating routine dosimetry systems for use in radiation processing, including establishing measurement traceability and estimating uncertainty in the measured dose using the calibrated dosimetry system.
NOTE 1—Regulations or other directives exist in many countries that govern certain radiation processing applications such as sterilization of healthcare products and radiation processing of food requiring that absorbed-dose measurements be traceable to national or international standards (ISO 11137-1, Refs (1-3)2).
The absorbed-dose range covered is up to 1 MGy.
The radiation types covered are photons and electrons with energies from 80 keV to 25 MeV.
This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 "Practice for Dosimetry in Radiation Processing" for the calibration of routine dosimetry systems. It is intended to be read in conjunction with ASTM E2628 and the relevant ASTM or ISO/ASTM standard practice for the dosimetry system being calibrated referenced in Section 2.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2 The boldface numbers given in parentheses refer to the bibliography at the end of this guide.