ASTM D7929 Standard Guide for Selection of Passive Techniques for Sampling Groundwater Monitoring Wells
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13.040
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13.040.30
- BSI BS ISO 17733 Workplace air Determination of mercury and inorganic mercury compounds Method by cold-vapour atomic absorption spectrometry or atomic fluorescence spectrometry
- BSI BS ISO 17733 Workplace air Determination of mercury and inorganic mercury compounds Method by cold-vapour atomic absorption spectrometry or atomic fluorescence spectrometry
- ASTM D4840 Standard Guide for Sample Chain-of-Custody Procedures
- ASTM D6911 Standard Guide for Packaging and Shipping Environmental Samples for Laboratory Analysis
- ASTM D5903 Standard Guide for Planning and Preparing for a Groundwater Sampling Event
- ASTM D7069 Standard Guide for Field Quality Assurance in a Ground-water Sampling Event
- Картотека зарубежных и международных стандартов
ASTM International
Standard Guide for Selection of Passive Techniques for Sampling Groundwater Monitoring Wells
N D7929
Annotation
This standard provides guidance and information on passive sampling techniques for collecting groundwater from monitoring wells. Passive groundwater samplers are able to acquire a sample at a discrete depth or interval in a well, without the active transport associated with a pump or purge technique (1).2 Passive groundwater sampling is a type of no-purge groundwater sampling method where the samplers are left in the well for a predetermined period of time prior to collecting the sample.
Methods for sampling monitoring wells include lowflow purging and sampling methods, traditional well-volume purging and sampling methods, post-purge grab sampling methods (for example, using a bailer), passive no-purge sampling methods, and active no-purge sampling methods such as using a bailer to collect a sample without purging the well. This guide focuses on passive no-purge sampling methodologies for collecting groundwater samples. These methodologies include the use of diffusion samplers, accumulation samplers, and passive-grab samplers. This guide provides information on the use, advantages, disadvantages, and limitations of each of these passive sampling technologies.
ASTM Standard D653 provides standard terminology relevant to soil, rock, and fluids contained in them. ASTM Standard D4448 provides a standard guide to sampling groundwater wells, and ASTM Standards D5903 and D6089 provide guides for planning and documenting a sampling event. Groundwater samples may require preservation (Guide D6517), filtration (Guide D6564), and measures to pack and ship samples (Guide D6911). Standard D7069 provides guidance on the quality control and quality assurance of sampling events. ASTM Standard D5092 provides standard practice for the design and installation of groundwater monitoring wells, ASTM Standard D5521 provides a standard guide for developing groundwater monitoring wells in granular aquifers, and D6452 provides a standard guide for purging methods used in groundwater quality investigations. Consult ASTM Standard D6724 for a guide on the installation of direct-push groundwater monitoring wells and ASTM Standard D6725 for a guide on the installation of direct-push groundwater monitoring wells with pre-pack screens.