ASTM D5806 Standard Test Method for Disinfectant Quaternary Ammonium Salts by Potentiometric Titration
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D2358 Standard Test Method for Separation of Active Ingredient from Surfactant and Syndet Compositions
- ASTM D820 Standard Test Methods for Chemical Analysis of Soaps Containing Synthetic Detergents
- ASTM D2357 Standard for Qualitative Classification of Surfactants by Infrared Absorption
- ASTM D2357 Standard for Qualitative Classification of Surfactants by Infrared Absorption
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- 13.040
- ASTM D7202 Standard Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
- ASTM D820 Standard Test Methods for Chemical Analysis of Soaps Containing Synthetic Detergents
- ASTM D1768 Standard Test Method for Sodium Alkylbenzene Sulfonate in Synthetic Detergents by Ultraviolet Absorption
- ASTM D4251 Standard Test Method for Active Matter in Anionic Surfactants by Potentiometric Titration
- ASTM D3049 Standard Test Method for Synthetic Anionic Ingredient by Cationic Titration
- ASTM D2358 Standard Test Method for Separation of Active Ingredient from Surfactant and Syndet Compositions
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Disinfectant Quaternary Ammonium Salts by Potentiometric Titration
N D5806
Annotation
This test method covers a potentiometric titration procedure for determining active matter in disinfectant quaternary ammonium salts. This test method is intended for the analysis of quaternary ammonium salts used as disinfectants, and only applies to the following commonly used quaternary ammonium salts: n-alkyldimethylbenzylammonium chloride (see Fig. 1), cetyltrimethylammonium chloride, and a blend of n-octyldecyl dimethylammonium chloride, di-n-octyl dimethylammonium chloride, and di-n-decyldimethyl ammonium chloride (see Fig. 2). Also, this test method can be applied to the analysis of disinfectant type products where the formula ingredients are known and the quaternary ammonium salt is one of the above. Interferences such as amines oxides and betaines present in disinfectant formulations were not tested.
This disinfectant quaternary ammonium salt conforms to the structures in Fig. 1 and Fig. 2.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary information, see Section 8.
Автоматический перевод:
Стандартный метод тестирования для дезинфицирующих четвертичных солей аммония потенциометрическим титрованием