ASTM F2985 Standard Practice for Installation of a PVC Segmental Panel Liner System in Man- Entry Size Sewers and Conduits
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13.220
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 13.220.40
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 19
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- 19.040
- ASTM G125 Standard Test Method for Measuring Liquid and Solid Material Fire Limits in Gaseous Oxidants
- ASTM F2984 Standard Specification for Segmental Panel System for the Grout-in-Place-Liner (GIPL) Rehabilitation Method of Existing Man-Entry Size Sewers, Culverts, and Conduits
- ASTM F2985 Standard Practice for Installation of a PVC Segmental Panel Liner System in Man- Entry Size Sewers and Conduits
- ASTM C827/C827M Standard Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Installation of a PVC Segmental Panel Liner System in Man- Entry Size Sewers and Conduits
N F2985
Annotation
The practice describes the procedures for the rehabilitation of gravity pipes, culverts, tunnels, and conduits by the installation of a field-fabricated PVC liner system. After installation of the liner system, cementitious grout is pumped into the annular space between the liner and the host structure. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC liner/grout/ existing pipe). This type of rehabilitation process is suitable for a variety of gravity pipe applications such as storm sewers, sanitary sewers, and culverts; and with geometries including circular, egg, ovoid, elliptical, arch, and site-specific composite shapes.
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.