ASTM E308 Standard Practice for Computing the Colors of Objects by Using the CIE System
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E2970 Standard Practice for Specifying Color by the Natural Colour System (NCS)
- 13
- ASTM D2105 Standard Test Method for Longitudinal Tensile Properties of “Fiberglass” (Glass-Fiber- Reinforced Thermosetting-Resin) Pipe and Tube
- ASTM E4 Standard Practices for Force Verification of Testing Machines
- ASTM E4 Standard Practices for Force Verification of Testing Machines
- ASTM E855 Standard Test Methods for Bend Testing of Metallic Flat Materials for Spring Applications Involving Static Loading
- ASTM E691 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ASTM D6478 Standard Test Method for Determining Specific Packability of Fabrics Used in Inflatable Restraints
- ASTM D1776/D1776M Standard Practice for Conditioning and Testing Textiles
- ASTM D6961/D6961M Standard Test Method for Color Measurement of Flax Fiber
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Computing the Colors of Objects by Using the CIE System
N E308
Annotation
This practice provides the values and practical computation procedures needed to obtain CIE tristimulus values from spectral reflectance, transmittance, or radiance data for objectcolor specimens.
Procedures and tables of standard values are given for computing from spectral measurements the CIE tristimulus values X, Y, Z, and chromaticity coordinates x, y for the CIE 1931 standard observer and X10, Y10, Z10 and x10. y10 for the CIE 1964 supplementary standard observer.
Standard values are included for the spectral power of six CIE standard illuminants and three CIE recommended fluorescent illuminants.
Procedures are included for cases in which data are available only in more limited wavelength ranges than those recommended, or for a measurement interval wider than that recommended by the CIE. This practice is applicable to spectral data obtained in accordance with Practice E1164 with 1-, 5-, 10-, or 20-nm measurement interval.
Procedures are included for cases in which the spectral data are, and those in which they are not, corrected for bandpass dependence. For the uncorrected cases, it is assumed that the spectral bandpass of the instrument used to obtain the data was approximately equal to the measurement interval and was triangular in shape. These choices are believed to correspond to the most widely used industrial practice.
This practice includes procedures for conversion of results to color spaces that are part of the CIE system, such as CIELAB and CIELUV (3). Equations for calculating color differences in these and other systems are given in Practice D2244.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.