ASTM D6831 Standard Test Method for Sampling and Determining Particulate Matter in Stack Gases Using an In-Stack, Inertial Microbalance
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D6831 Standard Test Method for Sampling and Determining Particulate Matter in Stack Gases Using an In-Stack, Inertial Microbalance
- ISO 25597 Stationary source emissions - Test method for determining PM2,5 and PM10 mass in stack gases using cyclone samplers and sample dilution - First Edition
- 13
- ISO 25597 Stationary source emissions - Test method for determining PM2,5 and PM10 mass in stack gases using cyclone samplers and sample dilution - First Edition
- 13.040
- DIN EN ISO 6185-3 Inflatable boats - Part 3: Boats with a hull length less than 8 m with a motor power rating of 15 kW and greater (ISO 6185-3:2014)
- ISO 8666 Small craft Principal data - First edition
- ISO 18854 Small craft - Reciprocating internal combustion engines exhaust emission measurement - Testbed measurement of gaseous and particulate exhaust emissions - First Edition
- ISO 8666 Small craft Principal data - First edition
- ISO 8666 Small craft Principal data - First edition
- ISO 18854 Small craft - Reciprocating internal combustion engines exhaust emission measurement - Testbed measurement of gaseous and particulate exhaust emissions - First Edition
- ISO 18854 Small craft - Reciprocating internal combustion engines exhaust emission measurement - Testbed measurement of gaseous and particulate exhaust emissions - First Edition
- ISO 8178-1 Reciprocating internal combustion engines Exhaust emission measurement Part 1: Test-bed measurement of gaseous and particulate exhaust emissions - Second Edition
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Sampling and Determining Particulate Matter in Stack Gases Using an In-Stack, Inertial Microbalance
N D6831
Annotation
This test method describes the procedures for determining the mass concentration of particulate matter in gaseous streams using an automated, in-stack test method. This method, an in-situ, inertial microbalance, is based on inertial mass measurement using a hollow tube oscillator. This method is describes the design of the apparatus, operating procedure, and the quality control procedures required to obtain the levels of precision and accuracy stated.
This method is suitable for collecting and measuring filterable particulate matter concentrations in the ranges 0.2 mg/m and above taken in effluent ducts and stacks.
This test method may be used for calibration of automated monitoring systems (AMS). If the emission gas contains unstable, reactive, or semi-volatile substances, the measurement will depend on the filtration temperature, and this method (and other in-stack methods) may be more applicable than out-stack methods for the calibration of automated monitoring systems.
This test method can be employed in sources having gas temperature up to 200°C and having gas velocities from 3 to 27 m/s.
This test method includes a description of equipment and methods to be used for obtaining and analyzing samples and a description of the procedure used for calculating the results.
Stack temperatures limitation for this test method is approximately 200°C [392°F].