ASTM D7220 Standard Test Method for Sulfur in Automotive, Heating, and Jet Fuels by Monochromatic Energy Dispersive X-ray Fluorescence Spectrometry
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87.060
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87.060.99
- ASTM D2374 Standard Test Method for Lead in Paint Driers by EDTA Method
- ASTM D2374 Standard Test Method for Lead in Paint Driers by EDTA Method
- ASTM D600 Standard Specification for Liquid Paint Driers
- ASTM D211 Standard Specification for Chrome Yellow and Chrome Orange Pigments
- ASTM D126 Standard Test Methods for Analysis of Yellow, Orange, and Green Pigments Containing Lead Chromate and Chromium Oxide Green
- ASTM D4814 REV A Standard Specification for Automotive Spark-Ignition Engine Fuel
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Sulfur in Automotive, Heating, and Jet Fuels by Monochromatic Energy Dispersive X-ray Fluorescence Spectrometry
N D7220
Annotation
This test method specifies an energy-dispersive X-ray fluorescence (EDXRF) method for the determination of total sulfur in automotive, No. 2 heating, and jet fuels with a concentration range of 3 to 942 mg/kg.
The pooled limit of quantitation of this test method as obtained by statistical analysis of inter laboratory test results is 3 mg/kg sulfur.
This test method is applicable to gasoline, oxygen enriched gasoline (RFG), diesel, diesel/biodiesel blends containing up to twenty volume percent biodiesel, kerosene, jet fuel, jet fuel/biodiesel blends containing up to five volume percent biodiesel and No. 2 home heating oil.
A fundamental assumption in this test method is that the standard and sample matrix is well matched. Matrix mismatch can be caused by C/H ratio differences between samples and standards or by the presence of other heteroatoms.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
The preferred concentration units are mg/kg sulfur.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Автоматический перевод: