ASTM E1870 Standard Test Method for Odor and Taste Transfer from Polymeric Packaging Film
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67.160
- ASTM E1879 Standard Guide for Sensory Evaluation of Beverages Containing Alcohol
- 67.160.10
- ASTM E2299 Standard Guide for Sensory Evaluation of Products by Children and Minors
- ASTM E1958 Standard Guide for Sensory Claim Substantiation
- ASTM E2262 Standard Practice for Estimating Thurstonian Discriminal Distances
- ASTM E2164 Standard Test Method for Directional Difference Test
- ASTM E460 Standard Practice for Determining Effect of Packaging on Food and Beverage Products During Storage
- ASTM E2609 Standard Test Method for Odor or Flavor Transfer or Both from Rigid Polymeric Packaging
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Odor and Taste Transfer from Polymeric Packaging Film
N E1870
Annotation
This test method covers a recommended procedure for examining odor and taste properties of polymeric film intended for use as flexible packaging materials. This test method can be used for single (mono) layers, coextruded, and laminate materials. The focus of this test method is the evaluation of the film in terms of its perceived inherent odor and the transfer of package-related odors, or flavors, or both, to water and other model systems (bland food simulants).
This test method assumes testing of the films at a one-time point; shelf-life testing is not included. Please see Ref (1)2 for discussion of shelf-life testing.
This test method can provide sample preparation procedures and two methods of evaluation. The Film Performance Score Method allows for the comparison of any film sample to another. The Ranking Method allows for comparison of samples within a set. The preparation of samples is consistent regardless of the method of evaluation used.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health precision and determine the applicability of regulatory limitations prior to use
2 The boldface numbers in parentheses refer to the list of references at the end of this standard.
Автоматический перевод:
Метод стандартной пробы для передачи аромата и вкуса от полимерной упаковочной пленки