ASTM E336 Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- 13
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- 13.220
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- 13.220.20
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- 23
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B40.200 Thermometers, Direct Reading and Remote Reading
- ASTM C1172 Standard Specification for Laminated Architectural Flat Glass
- ASTM F1642 Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings
- ASTM C1564 Standard Guide for Use of Silicone Sealants for Protective Glazing Systems
- ASTM C1193 Standard Guide for Use of Joint Sealants
- ASTM C919 Standard Practice for Use of Sealants in Acoustical Applications
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
N E336
Annotation
The sound isolation between two spaces in a building is determined by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, usually referred to as flanking paths. Fig. 1 illustrates the direct paths and some possible structural flanking paths. Additional non-structural flanking paths may include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms.
The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition including both direct and flanking transmission paths or the apparent sound insulation of the separating partition. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC), the normalized noise reduction (NNR) and normalized noise isolation class (NNIC), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC).With the exception of the ATL and ASTC under specified conditions, these procedures in the main part of the test method are only applicable when both room volumes are less than 150 m3.
NOTE 1—The word “partition” in this test method includes all types of walls, floors, or any other boundaries separating two spaces. The boundaries may be permanent, operable, or movable.
The NR and NIC between two locations may always be measured and reported though conditions present will influence how measurements are made. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed for all other measures and ratings in this standard. Thus, conditions may exist that will not allow NNR (NNIC), ATL (ASTC) or FTL (FSTC) to be measured. Where a partition between rooms is composed of parts that are constructed differently, or contains an element such as a door, it is not possible to measure the ATL and ASTC of the individual elements or portions of the partition. To evaluate the field performance of a door less than 6 m2 in area, use Test Method E2964.