ASTM E2236 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM E1362 Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells
- 31
- ASTM E1021 Standard Test Method for Spectral Responsivity Measurements of Photovoltaic Devices
- ASTM E1125 Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum
- ASTM E2236 Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
- ASTM E1040 Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules
N E2236
Annotation
These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules.
These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036.
These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036.
These test methods may be applied to cells and modules intended for concentrator applications.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Автоматический перевод:
Стандартные методы испытаний для измерения электрической работы и спектрального ответа мультисоединения неконцентратора фотогальванические клетки и модули