ASTM D5335 Standard Test Method for Linear Coefficient of Thermal Expansion of Rock Using Bonded Electric Resistance Strain Gauges
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 13
- ASTM D7380 Standard Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer
- 13.080
- 93
- ASTM D1140 Standard Test Methods for Determining the Amount of Material Finer than 75-?m (No. 200) Sieve in Soils by Washing
- ASTM D7382 Standard Test Methods for Determination of Maximum Dry Unit Weight and Water Content Range for Effective Compaction of Granular Soils Using a Vibrating Hammer
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Linear Coefficient of Thermal Expansion of Rock Using Bonded Electric Resistance Strain Gauges
N D5335
Annotation
This test method covers the laboratory determination of the linear (one-dimensional) coefficient of thermal expansion of rock using bonded electric resistance strain gauges. This test method is intended for evaluation of intact rock cores. Discontinuities in the rock mass, such as joints, inclusions, voids, veins, bedding, and the like can influence the thermal expansion of the rock, and judgment should be used when selecting the specimen to be analyzed in this test method.
This test method is applicable for unconfined stress states over the temperature range from 20 to 260°C.
NOTE 1-Unconfined tests performed at elevated temperatures may alter the mineralogy or grain structure of the test specimen. This alteration may change the physical and thermal properties of the test specimen.
NOTE 2-The strain gauges are mounted with epoxy. Most commercially available high temperature epoxies require elevated temperature curing. The elevated temperature required for this curing may alter the physical and thermal properties of the test specimen. Epoxy should be selected based upon the maximum expected test temperature. Room temperature curing epoxy should be used whenever practical.
The test specimens may be either saturated, dry or unsaturated. If saturated or unsaturated specimens are used, then the test temperature shall be at least 10°C less than the boiling point of the saturating fluid in order to reduce the effects of evaporation of the fluid.
NOTE 3-When testing a saturated specimen, the gravimetric water content of the specimen may change unless special precautions are taken to encapsulate the test specimen. Refer to 7.4.