ASTM D5381 Standard Guide for X-Ray Fluorescence (XRF) Spectroscopy of Pigments and Extenders
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D4940 Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blasting Abrasives
- ASTM F941 Standard Practice for Inspection of Marine Surface Preparation and Coating Application
- 47
- ASTM F941 Standard Practice for Inspection of Marine Surface Preparation and Coating Application
- 47.020
- ASTM F941 Standard Practice for Inspection of Marine Surface Preparation and Coating Application
- 47.020.05
- ISO 4677-1 Atmospheres for Conditioning and Testing - Determination of Relative Humidity - Part 1: Aspirated Psychrometer Method First Edition
- ISO 8502-4 Preparation of Steel Substrates Before Application of Paint and Related Products - Tests for the Assessment of Surface Cleanliness - Part 4: Guidance on the Estimation of the Probability of Condensation Prior to Paint Application - First Edition
- ISO 8502-4 Preparation of Steel Substrates Before Application of Paint and Related Products - Tests for the Assessment of Surface Cleanliness - Part 4: Guidance on the Estimation of the Probability of Condensation Prior to Paint Application - First Edition
- ASTM F718 Standard Specification for Shipbuilders and Marine Paints and Coatings Product/ Procedure Data Sheet
- ASTM D523 Standard Test Method for Specular Gloss
- ASTM D6763 Standard Guide for Testing Exterior Wood Stains and Clear Water Repellents
- ASTM D3925 Standard Practice for Sampling Liquid Paints and Related Pigmented Coatings
- Картотека зарубежных и международных стандартов
ASTM International
Standard Guide for X-Ray Fluorescence (XRF) Spectroscopy of Pigments and Extenders
N D5381
Annotation
This guide covers the general considerations for proper use of X-ray fluorescence (XRF) spectroscopy. Because many differences exist between XRF instruments, no detailed operating instructions are provided. The analyst should follow the instructions provided by the manufacturer for his instrument.
The analyst is encouraged to consult the chemical literature, various trade journals, pigment supplier publications, etc., as well as the instrument manuals from the manufacturer.
XRF is commonly employed to determine the elements present in inorganic pigments and extenders, often in concert with other analysis techniques. Organic pigments cannot normally be identified solely by XRF. On occasion, organic pigments contain heavier elements that can distinguish between major classes of these pigments or may serve to distinguish one of the two distinct pigments. However, the analyst should be wary of a qualitative pigment identification solely by XRF technique.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information see Section 3 on Radiation Concerns.
Автоматический перевод:
Типичный гид для спектроскопии Флуоресценции рентгена (XRF) пигментов и расширителей