ASTM F2248 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B1.20.1 Pipe Threads, General Purpose (Inch)
- 13
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B1.20.1 Pipe Threads, General Purpose (Inch)
- 13.220
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B1.20.1 Pipe Threads, General Purpose (Inch)
- 13.220.20
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B1.20.1 Pipe Threads, General Purpose (Inch)
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- 23
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B1.20.1 Pipe Threads, General Purpose (Inch)
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- ASME B40.200 Thermometers, Direct Reading and Remote Reading
- ASTM C1172 Standard Specification for Laminated Architectural Flat Glass
- ASTM F2248 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass
- ASTM C1564 Standard Guide for Use of Silicone Sealants for Protective Glazing Systems
- ASTM F1642 Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings
- ULC ULC/ORD-C199P-02 COMBUSTIBLE PIPING FOR SPRINKLER SYSTEMS - Second Edition
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass
N F2248
Annotation
This practice sets forth a method to specify an equivalent 3-second design loading suitable to use with Practice E1300 to select the thickness and type of blast resistant glazing fabricated with laminated glass to glaze a fenestration. Glass plies used to construct laminated glass are recommended to be either annealed or heat strengthened glass.
This practice applies to blast resistant glazing fabricated using laminated glass only, including single laminated glass and insulating glass fabricated with laminated glass. As a minimum, insulating glass shall use laminated glass for the inboard (protected side) lite.
This practice assumes that blast resistant glazing shall be adhered to its supporting frame using structural silicone sealant or adhesive glazing tape. The width of the structural silicone sealant bead shall be at least equal to the larger of 10-mm (3/8-in.) or the thickness designation of the glass to which it adheres but not larger than two times the thickness designation of the glass to which it adheres. The minimum thickness of the structural silicone bead shall be 5-mm (3 16- in.). The width of glazing tape shall be at least equal to two times but not more than four times the thickness designation of the glass to which it adheres. The width of silicone or glazing tape is referred to as bite and is shown and discussed in Guide C1564.
This practice assumes that the structural silicone bead or glazing tape is applied to both sides of single lite laminated glass but need only be applied to the inboard side (protected side) of insulating glass.
This practice assumes the framing members shall restrict deflections of edges of blast resistant glazing they support to L/60 under 2.0 the load resistance of the blast resistant glazing for inward loading, where L denotes the length of the supported edge.