SNV SN EN 1007-7 Advanced technical ceramics - Ceramic composites - Methods of test for reinforcements - Part 7: Determination of the distribution of tensile strength and of tensile strain to failure of filaments within a multifilament tow at high temperature
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60584-1 Thermocouples Part 1: Reference Tables - Edition 2.0
- 17
- IEC 60584-1 Thermocouples Part 1: Reference Tables - Edition 2.0
- 17.200
- IEC 60584-1 Thermocouples Part 1: Reference Tables - Edition 2.0
- 17.200.20
- IEC 60584-1 Thermocouples Part 1: Reference Tables - Edition 2.0
- CEN EN ISO 7500-1 Metallic materials - Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
- 77
- CEN EN ISO 7500-1 Metallic materials - Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
- 77.040
- CEN EN ISO 7500-1 Metallic materials - Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system
- SNV SN EN 1007-7 Advanced technical ceramics - Ceramic composites - Methods of test for reinforcements - Part 7: Determination of the distribution of tensile strength and of tensile strain to failure of filaments within a multifilament tow at high temperature
- CEN EN 1007-2 Advanced technical ceramics - Ceramics composites - Methods of test for reinforcement - Part 2: Determination of linear density
- Картотека зарубежных и международных стандартов
Schweizerische Normen-Vereinigung
Advanced technical ceramics - Ceramic composites - Methods of test for reinforcements - Part 7: Determination of the distribution of tensile strength and of tensile strain to failure of filaments within a multifilament tow at high temperature
N SN EN 1007-7
Annotation
This European standard specifies the conditions, apparatus and procedure for determining the distribution of tensile strength and tensile strain to failure of ceramic filaments in multifilament tows at high temperature in air, vacuum or a controlled inert atmosphere.
This part of EN 1007 applies to tows of continuous ceramic filaments, which are assumed to act freely and independently under loading and behave linearly elastic up to failure.
Two methods are proposed depending on the temperature of the ends of the tow:
a) hot end method;
NOTE 1 The application of the hot end method is restricted by ceramic glues with sufficient shear strengths at the test temperature. Current experience with this technique is limited to 1 300 °C, because of the maximum application temperature of ceramic glues.
b) cold end method.
NOTE 2 The cold-end method is limited to 1 700 °C in air and 2 000 °C in inert atmosphere because of the limits of furnaces.
Both methods allow for a failure rate in the determination of distribution of tensile strain and tensile strength.
Автоматический перевод: