ASTM C1301 Standard Test Method for Major and Trace Elements in Limestone and Lime by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP) and Atomic Absorption (AA)
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM C977 Standard Specification for Quicklime and Hydrated Lime for Soil Stabilization
- ASTM F2618 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems
- 23
- ASTM F2618 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems
- 23.040
- ASTM F2618 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems
- 23.040.20
- ASTM C91/C91M Standard Specification for Masonry Cement
- ASTM C110 Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone
- ASTM C1707 Standard Specification for Pozzolanic Hydraulic Lime for Structural Purposes
- ASTM C51 Standard Terminology Relating to Lime and Limestone (as used by the Industry)
- ASTM C1097 Standard Specification for Hydrated Lime for Use in Asphalt Cement or Bituminous Paving Mixtures
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Major and Trace Elements in Limestone and Lime by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP) and Atomic Absorption (AA)
N C1301
Annotation
The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Methods 200.7 and 200.9.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Автоматический перевод:
Метод стандартной пробы для главного и микроэлементов в известняке и извести индуктивно двойной плазменно-атомной спектроскопией эмиссии (ICP) и атомным поглощением (AA)
Следующий метод испытаний покрывает использование индуктивно двойной плазменно-атомной спектроскопии эмиссии (ICP) и атомно-абсорбционной спектроскопии (AA) в анализе главных и микроэлементов в известняке и извести (сожженный известняк).