ASTM D6071 Standard Test Method for Low Level Sodium in High Purity Water by Graphite Furnace Atomic Absorption Spectroscopy
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D5900 Standard Specification for Physical and Chemical Properties of Industry Reference Materials (IRM)
- 19
- 83
- BSI BS EN 62535 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil - CORR: February 28, 2011
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- ASTM D7150 Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids Under Thermal Stress
- ASTM D3612 Standard Test Method for Analysis of Gases Dissolved in Electrical Insulating Oil by Gas Chromatography
- ASTM D2140 Standard Practice for Calculating Carbon-Type Composition of Insulating Oils of Petroleum Origin
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Low Level Sodium in High Purity Water by Graphite Furnace Atomic Absorption Spectroscopy
N D6071
Annotation
This test method covers the determination of trace sodium in high purity water. The method range of concentration is 1 to 40 g/L sodium. The analyst may extend the range once its applicability has been ascertained.
NOTE 1-It is necessary to perform replicate analysis and take an average to accurately determine values at the lower end of the stated range.
This test method is a graphite furnace atomic absorption spectrophotometric method for the determination of trace sodium impurities in ultra high purity water.
This test method has been used successfully with a high purity water matrix.2 It is the responsibility of the analyst to determine the suitability of the test method for other matrices.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2 RP2712 Sub Program-Grab Sample Method Validation Report Results, Electric Power Research Institute, Palo Alto, CA, 1987.
*A Summary of Changes section appears at the end of this standard
Автоматический перевод: