ASTM D6807 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from 2 to 100 Mue S/cm
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D3558 Standard Test Methods for Cobalt in Water
- 13
- ASTM D3558 Standard Test Methods for Cobalt in Water
- 13.060
- ASTM D3558 Standard Test Methods for Cobalt in Water
- 13.060.50
- ASTM D3558 Standard Test Methods for Cobalt in Water
- ASTM D3559 Standard Test Methods for Lead in Water
- ASTM D858 Standard Test Methods for Manganese in Water
- API RP 45 Recommended Practice for Analysis of Oilfield Waters - THIRD EDITION
- ASTM D512 Standard Test Methods for Chloride Ion In Water
- ASTM D5615 Standard Test Method for Operating Characteristics of Home Reverse Osmosis Devices
- ASTM D1293 Standard Test Methods for pH of Water
- ASTM D6807 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from 2 to 100 Mue S/cm
- ASTM D513 Standard Test Methods for Total and Dissolved Carbon Dioxide in Water
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from 2 to 100 Mue S/cm
N D6807
Annotation
This test method covers the determination of the operating characteristics of continuous electrodeionization (CEDI) devices, indicative of deionization performance when a device is applied to production of highly deionized water from the product water of a reverse osmosis system. This test method is a procedure applicable to feed waters containing carbonic acid and/or dissolved silica and other solutes, with a conductivity range of approximately 2 to 100 microsiemens-cm-1.
This test method covers the determination of operating characteristics under standard test conditions of CEDI devices where the electrically active transfer media therein is predominantly regenerated.
The test method is not necessarily indicative of:
Long term performance on feed waters containing foulants and/or sparingly soluble solutes;
Performance on feeds of brackish water, sea water, or other high salinity feeds;
Performance on synthetic industrial feed solutions, pharmaceuticals, or process solutions of foods and beverages; or,
Performance on feed waters less than 2 S/cm, particularly performance relating to organic solutes, colloidal or particulate matter, or biological or microbial matter.
The test method, subject to the limitations described, can be applied as either an aid to predict expected deionization performance for a given feed water quality, or as a method to determine whether performance of a given device has changed over some period of time. It is ultimately, however, the user's responsibility to ensure the validity of the test method for their specific applications.