ASTM D1218 Standard Test Method for Refractive Index and Refractive Dispersion of Hydrocarbon Liquids
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D5900 Standard Specification for Physical and Chemical Properties of Industry Reference Materials (IRM)
- 19
- 83
- BSI BS 148 Reclaimed mineral insulating oil for transformers and switchgear – Specification
- BSI BS EN 62535 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil - CORR: February 28, 2011
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- BSI BS EN 62535 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil - CORR: February 28, 2011
- BSI BS EN 62535 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil - CORR: February 28, 2011
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- DIN 51353 Testing of insulating oils; detection of corrosive sulfur; silber strip test
- CEI EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- ASTM D7150 Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids Under Thermal Stress
- ASTM D3612 Standard Test Method for Analysis of Gases Dissolved in Electrical Insulating Oil by Gas Chromatography
- ASTM D2140 Standard Practice for Calculating Carbon-Type Composition of Insulating Oils of Petroleum Origin
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Refractive Index and Refractive Dispersion of Hydrocarbon Liquids
N D1218
Annotation
This test method covers the measurement of refractive index, accurate to four decimal places or better, of transparent and light-colored hydrocarbons in the range of 1.3300 to 1.5000 at temperatures from 20 to 30°C by manual (opticalmechanical) or automatic (digital) procedure.
The manual (optical-mechanical) procedure also covers the measurement of refractive dispersion accurate to the fourth decimal place or better.
NOTE 1-The test method may be suitable for measuring the refractive indices of liquids above 1.5000 and at temperatures both below 20°C and above 30°C; however, the test method precision may not apply. Verification of the accuracy of such measurements will depend upon the availability of reliable, certified reference standards that demonstrate the performance of the instrument used under the particular measuring conditions.
The test method may not be applicable to liquids that are strongly colored, or that have bubble points so near the test temperature that a reading cannot be obtained before substantial weathering takes place. Liquid color should be limited to No. 4 ASTM Color or lighter, as determined by Test Method D1500.
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
WARNING-Mercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA's website-http://www.epa.gov/mercury/faq.htm-for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.