ISO/ASTM 51607 Standard Practice for Use of the Alanine-EPR Dosimetry System

Список продуктов
Данный раздел/документ содержится в продуктах:

 

ASTM International

Standard Practice for Use of the Alanine-EPR Dosimetry System
 N ISO/ASTM 51607

 

Annotation

 

This practice covers dosimeter materials, instrumentation, and procedures for using the alanine-EPR dosimetry system for measuring the absorbed dose in the photon and electron radiation processing of materials. The system is based on electron paramagnetic resonance (EPR) spectroscopy of free radicals derived from the amino acid alanine.2

The alanine dosimeter is classified as a type I dosimeter as it is affected by individual influence quantities in a welldefined way that can be expressed in terms of independent correction factors (see ASTM Practice E2628). The alanine dosimeter may be used in either a reference standard dosimetry system or in a routine dosimetry system.

This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 "Practice for Dosimetry in Radiation Processing" for alanine dosimetry system. It should be read in conjunction with ASTM E2628.

This practice covers alanine-EPR dosimetry systems for dose measurements under the following conditions:

The absorbed dose range is between 1 and 1.5 3 105Gy.

The absorbed dose rate is up to 102Gy s-1 for continuous radiation fields and up to 3 X 1010Gy s-1 for pulsed radiation fields (1-4).3

The radiation energy for photons and electrons is between 0.1 and 30 MeV (1, 2, 5-8).

The irradiation temperature is between –78 °C and + 70 °C (2, 9-12).