DIN EN 61158-5-12 Industrial communication networks - Fieldbus specifications - Part 5-12: Application layer service definition - Type 12 elements (IEC 61158-5-12:2014)
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 13
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 13.160
- 35
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 35.100
- CENELEC CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- 35.100.05
- CEI CLC/TR 62685 Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
- IEC 61326-3-1 CORR 1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications CORRIGENDUM1 - Edition 1.0
- IEC 61326-3-1 CORR 1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications CORRIGENDUM1 - Edition 1.0
- Картотека зарубежных и международных стандартов
Deutsches Institut fur Normung e. V.
Industrial communication networks - Fieldbus specifications - Part 5-12: Application layer service definition - Type 12 elements (IEC 61158-5-12:2014)
N EN 61158-5-12
Annotation
General
The fieldbus Application Layer (FAL) provides user programs with a means to access the fieldbus communication environment. In this respect, the FAL can be viewed as a “window between corresponding application programs.”
This standard provides common elements for basic time-critical and non-time-critical messaging communications between application programs in an automation environment and material specific to Type 12 fieldbus. The term “time-critical” is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life.
This standard defines in an abstract way the externally visible service provided by the different Types of the fieldbus Application Layer in terms of
a) an abstract model for defining application resources (objects) capable of being manipulated by users via the use of the FAL service,
b) the primitive actions and events of the service;
c) the parameters associated with each primitive action and event, and the form which they take; and
d) the interrelationship between these actions and events, and their valid sequences.
The purpose of this standard is to define the services provided to