API TR 6F2 Technical Report on Fire Resistance Improvements for API Flanges - Third Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- API SPEC 6AV1 Specification for Verification Test of Wellhead Surface Safety Valves and Underwater Safety Valves for Offshore Service - First Edition; Errata - December 1996
- API TR 6F2 Technical Report on Fire Resistance Improvements for API Flanges - Third Edition
- API RP 17A Design and Operation of Subsea Production Systems - General Requirements and Recommendations - Fourth Edition; ISO 13628-1:2005 Adoption
- SNV SN EN 14359+A1 Gas-loaded accumulators for fluid power applications
- 23
- SNV SN EN 14359+A1 Gas-loaded accumulators for fluid power applications
- 23.100
- ISO 10945 Hydraulic Fluid Power - Gas-Loaded Accumulators - Dimensions of Gas Ports - First Edition
- API STD 2RD Dynamic Risers for Floating Production Systems - Second Edition
- API TR 6AF Technical Report on Capabilities of API Flanges Under Combinations of Load - Third Edition
- API SPEC 6FB API Specification for Fire Test for End Connections - Third Edition; Errata 08/20/2006; Supplement 12/18/2006
- Картотека зарубежных и международных стандартов
American Petroleum Institute
Technical Report on Fire Resistance Improvements for Flanges - Third Edition
N TR 6F2
Annotation
1 Scope
This document establishes recommended methods for improving the performance of standard API flanges when subjected to the adverse effects of external high temperatures induced by exposure to fires. It does not cover fire prevention, suppression, or fire fighting practices.
Innumerable factors contribute to flange failures under fire conditions, so it is difficult to formulate hard and fast engineering rules which will ensure fire resistant behavior under all circumstances. It is possible to formulate a generalized methodology to examine enhancements which will increase the probability of survival of API flanges under fire conditions.
1.1 COMPARATIVE TESTING
To provide a basis for comparing protection methods it is necessary to provide consistent testing criteria. Although primarily used for valves, API RP 6F and API Spec 6FA, as well as other test procedures, listed in the following, have been used for testing connection and seal performances.
a. API RP 6F.
b. API Spec 6FA (supersedes API RP 6F).
c. User Modified API RP 6F, (Appendix A).
d. API Spec 6FB--Should be considered as the standard test method.
It is not intended that the order of listing indicates test severity.