IEC 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments - Edition 2.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- 29
- IEC 60079-11 CORR 1 Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “I” - Edition 6.0
- 29.260
- CEN CEN/CLC/TR 16832 Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
- IEC 60079-0 Explosive atmospheres – Part 0: Equipment – General requirements - Edition 6.0; The contents of the corrigendum of November 2012 have been included in this copy
- BSI BS EN 60079-10-1 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
- IEC 60079-0 Explosive atmospheres – Part 0: Equipment – General requirements - Edition 6.0; The contents of the corrigendum of November 2012 have been included in this copy
- BSI BS EN 60079-10-1 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
- BSI BS EN 60079-6 Explosive atmospheres - Part 6: Equipment protection by oil immersion “o” - AMD: June 30, 2008
- BSI BS EN 13922 Tanks for transport of dangerous goods - Service equipment for tanks - Overfill prevention systems for liquid fuels
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments - Edition 2.0
N 61000-6-2
Annotation
This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in industrial environments, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.
This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.
This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations.
The environments encompassed by this standard are industrial, both indoor and outdoor.
Industrial locations are in addition characterised by the existence of one or more of the following:
– industrial, scientific and medical (ISM) apparatus (as defined in CISPR 11);
– heavy inductive or capacitive loads are frequently switched;
– currents and associated magnetic fields are high.
The object of this standard is to define immunity test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.



