Annotation

 

This part of EN 50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low-voltage power installation as the transmission medium. This part of EN 50561 applies to equipment that communicate over this medium in the frequency range 1,606 5 MHz to 30 MHz.

NOTE Similar equipment that communicate outside this frequency range is under study and will be covered by another European Standard.

Procedures are given for the measurement of signals generated by the equipment and limits are specified for the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limit is specified.

 

Автоматический перевод:

 

Аппарат связи по линиям электросети, используемый в низковольтных установках - Радио-характеристиках волнения - Пределах и методах измерения - Часть 1: Аппарат для в бытовом применении

Эта часть EN 50561 указывает пределы и методы измерения радио-характеристик нарушения для коммуникационного аппарата в доме, которые используют низковольтную силовую установку в качестве среды передачи. Эта часть EN 50561 относится к оборудованию, которые передают по этому носителю в частотном диапазоне 1,606 от 5 МГц до 30 МГц.