CEI EN 62271-107 High-voltage switchgear and controlgear Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches - Edition 1.2; Consolidated Reprint
- 29
- IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches - Edition 1.2; Consolidated Reprint
- 29.130
- IEC TR 62655 Tutorial and application guide for high-voltage fuses - Edition 1.0
- CENELEC EN 60282-1 High-voltage fuses - Part 1: Current-limiting fuses - Incorporates Amendment A1: 2014
- IEC 62271-105 High-voltage switchgear and controlgear – Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV - Edition 2.0
- Картотека зарубежных и международных стандартов
Comitato Elettrotecnico Italiano
High-voltage switchgear and controlgear Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
N EN 62271-107
Annotation
Subclause 1.1 of IEC 62271-1:2007 is not applicable, and is replaced as follows.
This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of:
– breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current;
– making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.
They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits.
Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher.
NOTE 1 In this standard the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity.
This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8.