IEC 62612 Self-ballasted LED lamps for general lighting services with supply voltages > 50 V – Performance requirements - Edition 1.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- IEC 60630 AMD 6 AMENDMENT 6 Maximum lamp outlines for incandescent lamps - Edition 2.0
- 29
- IEC TS 60479-1 CORR 1 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 1 - Edition 4.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TR 60479-4 Effects of current on human beings and livestock – Part 4: Effects of lightning strokes - Edition 2.0
- IEC TS 60479-1 CORR 2 Effects of current on human beings and livestock – Part 1: General aspects CORRIGENDUM 2 - Edition 4.0
- IEC 61230 Live working – Portable equipment for earthing or earthing and short-circuiting - Edition 2.0
- CEI EN 60357 Tungsten halogen lamps (non-vehicle) - Performance specifications
- IEC TR 61341 Method of measurement of centre beam intensity and beam angle(s) of reflector lamps - Edition 2.0
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Self-ballasted LED lamps for general lighting services with supply voltages > 50 V – Performance requirements - Edition 1.0
N 62612
Annotation
This International Standard specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having:
• a rated power up to 60 W;
• a rated voltage of > 50 V a.c. up to 250 V a.c.;
• a lamp cap as listed in IEC 62560.
These performance requirements are additional to the safety requirements in IEC 62560.
The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines.
The requirements of this standard relate to type testing. This standard covers LED lamps that intentionally produce white light, based on inorganic LEDs.
Recommendations for whole product testing or batch testing are under consideration.
The life time of LED lamps is in most cases much longer than the practical test times. Consequently, verification of manufacturer's life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardised. For that reason the acceptance or rejection of a manufacturer's life time claim, past an operational time as stated in 7.1, is out of the scope of this standard.
Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation character categories showing behaviour in agreement with manufacturer's information, provided before the test is started.