ASTM F458 Standard Practice for Nondestructive Pull Testing of Wire Bonds
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D1039 Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation
- 29
- ASTM D1039 Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation
- 29.035
- ASTM D1039 Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation
- 29.035.50
- ASTM D1039 Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation
- ASTM F79 Standard Specification for Type 101 Sealing Glass
- ASTM D257 Standard Test Methods for DC Resistance or Conductance of Insulating Materials
- ASTM D116 Standard Test Methods for Vitrified Ceramic Materials for Electrical Applications
- ASTM D257 Standard Test Methods for DC Resistance or Conductance of Insulating Materials
- ASTM D116 Standard Test Methods for Vitrified Ceramic Materials for Electrical Applications
- ASTM D2149 Standard Test Method for Permittivity (Dielectric Constant) And Dissipation Factor Of Solid Dielectrics At Frequencies To 10 MHz And Temperatures To 500°C
- ASTM D2442 Standard Specification for Alumina Ceramics for Electrical and Electronic Applications
- DLA MIL-STD-883K CHANGE 1 TEST METHOD STANDARD MICROCIRCUITS
- ASTM F458 Standard Practice for Nondestructive Pull Testing of Wire Bonds
- ASTM F459 Standard Test Methods for Measuring Pull Strength of Microelectronic Wire Bonds
- Картотека зарубежных и международных стандартов
ASTM International
Standard Practice for Nondestructive Pull Testing of Wire Bonds
N F458
Annotation
This practice covers nondestructive testing of individual wire bonds made by either ultrasonic, thermal compression or thermosonic techniques. The test is intended to reveal (by breaking) nonacceptable wire bonds but is designed to avoid damage to acceptable wire bonds.
NOTE 1-Common usage at the present time considers the term "wire bond" to include the entire interconnection: both welds and the intervening wire span.
The practice covers wire bonds made with smalldiameter (from 0.0007 to 0.003-in. (18 to 76- m)) wire such as the type used in integrated circuits and hybrid microcircuits, system in package, and so forth.
This practice can be used only when the loop height of the wire bond is large enough to allow a suitable hook for pulling to be placed under the wire.
While the procedure is applicable to wire of any composition and metallurgical state, criteria are given only for gold and aluminum wire.
A destructive pull test is used on wire bonds of the same type and geometry to provide the basis for the determination of the nondestructive pulling force to be used in this practice. This may only be used if the sample standard deviation, s, of the pulling forces required to destroy at least 25 of the same wire bonds tested by the destructive pull-test method is less than or equal to 0.25 of the sample average, x-. If s > 0.25 x-, this practice may not be used.
NOTE 2-If s > 0.25 x-, some aspect of the bonding process is out of control. Following corrective action, the destructive pull-test measurements should be repeated to determine if the s < 0.25 x- criterion is met.