ULC CAN/ULC-S774-09 STANDARD LABORATORY GUIDE FOR THE DETERMINATION OF VOLATILE ORGANIC COMPOUND EMISSIONS FROM POLYURETHANE FOAM - SECOND EDITION
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ULC CAN/ULC-S705.1-01 STANDARD FOR THERMAL INSULATION – SPRAY APPLIED RIGID POLYURETHANE FOAM, MEDIUM DENSITY – MATERIAL - SPECIFICATION - Second Edition; Including Amendment 1: 08/2004; Amendment 2: 06/2005 and Amendment 3: 3/2011
- 91
- ULC CAN/ULC-S705.1-01 STANDARD FOR THERMAL INSULATION – SPRAY APPLIED RIGID POLYURETHANE FOAM, MEDIUM DENSITY – MATERIAL - SPECIFICATION - Second Edition; Including Amendment 1: 08/2004; Amendment 2: 06/2005 and Amendment 3: 3/2011
- 91.120
- ULC CAN/ULC-S705.1-01 STANDARD FOR THERMAL INSULATION – SPRAY APPLIED RIGID POLYURETHANE FOAM, MEDIUM DENSITY – MATERIAL - SPECIFICATION - Second Edition; Including Amendment 1: 08/2004; Amendment 2: 06/2005 and Amendment 3: 3/2011
- 91.120.10
- ULC CAN/ULC-S773-09 STANDARD FOR THERMAL INSULATION TERMINOLOGY - Second Edition
- ULC CAN/ULC-S773-09 STANDARD FOR THERMAL INSULATION TERMINOLOGY - Second Edition
- ULC CAN/ULC-S773-09 STANDARD FOR THERMAL INSULATION TERMINOLOGY - Second Edition
- Картотека зарубежных и международных стандартов
Underwriters' Laboratories of Canada
STANDARD LABORATORY GUIDE FOR THE DETERMINATION OF VOLATILE ORGANIC COMPOUND EMISSIONS FROM POLYURETHANE FOAM - SECOND EDITION
N CAN/ULC-S774-09
Annotation
This laboratory guide has been developed for the assessment of volatile organic compound emissions from materials used in residential buildings.
This laboratory guide specifies recommended procedures for the use of test chambers to evaluate emissions from the material at a point in time following its installation. The guide contains the following:
A A head-space analysis procedure for initial identification of volatile organic compounds released by the material;
B Two dynamic chamber procedures (A and B) for characterizing the rate of volatile organic compound emissions from the material; and
C A methodology for calculating the estimated indoor air concentrations of volatile organic compounds based on the results of dynamic chamber testing.
The head-space analysis is a static test to identify significant amounts of emitted compounds from the material. It is followed by either dynamic chamber Procedure A or B.
Procedure A measures the typical VOC emission characteristics of the material. The test is conducted after conditioning the specimen for 30 d.
Procedure B measures the typical VOC emission profile of the material commencing 24 h after installation and continuing for 30 d thereafter.
The results of Procedures A or B are used to calculate indoor air VOC concentration profiles and to determine the acceptability of the material for new construction and/or retrofit use.