UNI EN 488 District heating pipes - Preinsulated bonded pipe systems for directly buried hot water networks - Steel valve assembly for steel service pipes, polyurethane thermal insulation and outer casing of polyethylene
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- 23
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- 23.060
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- 23.060.01
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- SNV SN EN 13789 Industrial valves - Cast iron globe valves
- ISO 5210 Industrial Valves - Multi-Turn Valve Actuator Attachments First Edition - First Eidtion
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- ISO 5210 Industrial Valves - Multi-Turn Valve Actuator Attachments First Edition - First Eidtion
- ISO 5210 Industrial Valves - Multi-Turn Valve Actuator Attachments First Edition - First Eidtion
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 13789 Industrial valves - Cast iron globe valves
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 12266-1 Industrial valves - Testing of metallic valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements
- UNI EN 488 District heating pipes - Preinsulated bonded pipe systems for directly buried hot water networks - Steel valve assembly for steel service pipes, polyurethane thermal insulation and outer casing of polyethylene
- UNI EN ISO 6708 Pipework components. Definition and selection of DN (nominal size).
- UNI EN 12570 Industrial valves - Method for sizing the operating element
- Картотека зарубежных и международных стандартов
Ente Nazionale Italiano di Unificazione
District heating pipes - Preinsulated bonded pipe systems for directly buried hot water networks - Steel valve assembly for steel service pipes, polyurethane thermal insulation and outer casing of polyethylene
N UNI EN 488
Annotation
This European Standard specifies requirements and test methods for valves of prefabricated thermally insulated valve assemblies comprising a steel valve, rigid polyurethane foam insulation and an outer casing of polyethylene for use in directly buried hot water networks with pre-insulated pipe assemblies in accordance with EN 253.
This European Standard applies only to insulated valve assemblies for continuous operation with hot water at various temperatures in accordance with EN 253:2009, Clause 1 and the valve assemblies with a maximum operation pressure of 25 bar. For higher pressures, additional demands apply.
Guidelines for quality inspection are given in Annex A of this European Standard.
NOTE For this application, the following valve types are commonly used: ball valves, gate valves, and butterfly valves.
This European Standard does not include calculation rules for loads and stresses. These depend on the configuration of the system as it is installed. The design and installation rules are given in EN 13941:2009+A1:2010.
Автоматический перевод:
Трубы теплоцентрали - Предварительно изолированные связанные системы труб для непосредственно проложенных под землей сетей горячей воды - сборка Стального клапана для стальных сервисных труб, полиуретан тепловая изоляция и внешний корпус полиэтилена



