CENELEC EN 50543 Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air - Requirements and test methods
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CEN EN 50270 Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
- 13
- 19
- 33
- CENELEC EN 50194-2 Electrical apparatus for the detection of combustible gases in domestic premises Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises - Additional test methods and performance requirements - Incorporates Amendment A1: 2016
- BSI BS EN 50270 Electromagnetic Compatibility - Electrical Apparatus for the Detection and Measurement of Combustible Gases, Toxic Gases or Oxygen
- Картотека зарубежных и международных стандартов
European Committee for Electrotechnical Standardization
Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air - Requirements and test methods
N EN 50543
Annotation
This European Standard specifies requirements for the construction, testing and performance of electronic portable and transportable apparatus for the detection and measurement of carbon dioxide (CO2) and/or carbon monoxide (CO) in indoor ambient air, which includes air entering mechanical ventilation systems in domestic residential, commercial and industrial premises and public buildings.
This European Standard includes indoor air quality apparatus with CO and CO2 measuring capabilities.
This European Standard excludes:
• apparatus used in workplace atmospheres for the direct detection and direct concentration measurement of toxic gases and vapours (i.e. conforming to EN 45544 series);
• electronic portable combustion gas analysers (i.e. conforming to EN 50379 series);
• apparatus for the detection of carbon monoxide in domestic premises (i.e. conforming to EN 50291 series).
NOTE 1 Examples of applications are monitoring indoor air quality, measuring CO and/or CO2 concentrations in commercial laundry and kitchen environments, assessing the safe operation of appliances installed in compartments.
NOTE 2 When this apparatus is used in industrial premises national regulations may apply.