IEC TS 60695-7-50 Fire hazard testing Part 7-50: Toxicity of fire effluent Estimation of toxic potency Apparatus and test method - Edition 1.0
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ISO 13344 Estimation of the lethal toxic potency of fire effluents - Second Edition
- 13
- ISO 13344 Estimation of the lethal toxic potency of fire effluents - Second Edition
- 13.220
- ISO 13344 Estimation of the lethal toxic potency of fire effluents - Second Edition
- 13.220.99
- IEC TR 62222 Fire performance of communication cables installed in buildings - Edition 2.0
- CENELEC EN 50289-4-11 Communication Cables - Specifications for Test Methods Part 4-11: Environmental Test Methods - a Horizontal Integrated Fire Test Method
- IEC TR 60695-8-2 Fire hazard testing – Part 8-2: Heat release – Summary and relevance of test methods - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC 60695-1-11 Fire hazard testing – Part 1-11: Guidance for assessing the fire hazard of electrotechnical products – Fire hazard assessment - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC TR 60695-8-2 Fire hazard testing – Part 8-2: Heat release – Summary and relevance of test methods - Edition 2.0
- CENELEC EN 50289-4-11 Communication Cables - Specifications for Test Methods Part 4-11: Environmental Test Methods - a Horizontal Integrated Fire Test Method
- CENELEC EN 50289-4-11 Communication Cables - Specifications for Test Methods Part 4-11: Environmental Test Methods - a Horizontal Integrated Fire Test Method
- IEC TR 60695-8-2 Fire hazard testing – Part 8-2: Heat release – Summary and relevance of test methods - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC 60695-1-11 Fire hazard testing – Part 1-11: Guidance for assessing the fire hazard of electrotechnical products – Fire hazard assessment - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC TR 60695-8-2 Fire hazard testing – Part 8-2: Heat release – Summary and relevance of test methods - Edition 2.0
- IEC TR 60695-8-2 Fire hazard testing – Part 8-2: Heat release – Summary and relevance of test methods - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC 60695-1-11 Fire hazard testing – Part 1-11: Guidance for assessing the fire hazard of electrotechnical products – Fire hazard assessment - Edition 2.0
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- BSI BS EN 60695-8-1 Fire hazard testing - Part 8-1: Heat release - General guidance
- IEC 60695-1-11 Fire hazard testing – Part 1-11: Guidance for assessing the fire hazard of electrotechnical products – Fire hazard assessment - Edition 2.0
- IEC 60695-1-11 Fire hazard testing – Part 1-11: Guidance for assessing the fire hazard of electrotechnical products – Fire hazard assessment - Edition 2.0
- IEC 60695-1-10 Fire hazard testing – Part 1-10: Guidance for assessing the fire hazard of electrotechnical products – General guidelines - Edition 1.0
- IEC TS 60695-7-50 Fire hazard testing Part 7-50: Toxicity of fire effluent Estimation of toxic potency Apparatus and test method - Edition 1.0
- IEC TS 60695-7-51 Fire Hazard Testing - Part 7-51: Toxicity of Fire Effluent - Estimation of Toxic Potency: Calculation and Interpretation of Test Results - Edition 1.0
- Картотека зарубежных и международных стандартов
International Electrotechnical Commission
Fire hazard testing Part 7-50: Toxicity of fire effluent Estimation of toxic potency Apparatus and test method - Edition 1.0
N TS 60695-7-50
Annotation
This technical specification describes a test method for the generation of fire effluent and the identification and measurement of its constituent combustion products. It uses a moving test specimen and a tube furnace at different temperatures and air flow rates as the fire model. This test method is designed to reproduce certain decomposition conditions in a range of fire types characterized in ISO/TR 9122-1.
Stage 1b Non-flaming decomposition (oxidative)
Stage 2 Developing fire (flaming)
Stage 3a Fully developed fire (flaming), relatively low ventilation
The method described in this technical specification is designed to model closely all three of these major fire stages, and also has the potential to model others as necessary. In this test, the measurement of fire effluent is made using material test specimens, which may be taken from end-products, or, if the apparatus and method allow, may be an end-product.
Toxic potency values are only of use in toxic hazard estimations, and must not be used in isolation.
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications.
Автоматический перевод: