0 продуктов

Авторизация

NR TI 033 ISSUE 1 DOUBLE CUTTING OF BACK CONTACTS IN SAFETY CRITICAL CIRCUITS

Список продуктов
Данный раздел/документ содержится в продуктах:

 

Network Rail

DOUBLE CUTTING OF BACK CONTACTS IN SAFETY CRITICAL CIRCUITS
 N TI 033 ISSUE 1

 

Annotation

 

Introduction

The principle of double cutting of safety critical circuits to avoid the risk of an earth fault bridging out contacts in one leg of a circuit has been a long standing principle. GI/GN7517 details the measures to be taken to prevent such a risk and also lists some situations where double cutting may not be appropriate.

In a recent issue of typical circuits for LED signals, the decision was made to double cut the feeds to signal heads since this provided a safety benefit, however this was applied to both front and back contacts. Subsequent review has concluded that whilst double cutting the feed to, for instance, the red aspect provides a safety benefit with regard to earth faults, it increases the risk of failure preventing the critical indication being displayed.

 

Автоматический перевод:

 

ДВАЖДЫ СОКРАЩЕНИЕ НЕПОДВИЖНЫХ КОНТАКТОВ В БЕЗОПАСНЫХ КРИТИЧЕСКИХ СХЕМАХ

Введение

Принцип двойного сокращения безопасности, с которой критические схемы для предотвращения риска наземного отказа, соединяющего, связываются на одном участке схемы, был давнишним принципом. GI/GN7517 детализирует меры, которые будут взяты для предотвращения такого риска и также перечисляет некоторые ситуации, где двойное сокращение не может быть соответствующим.

Категории продуктов

 

 

 

Знакомьтесь, "Техэксперт"

 Техэксперт для iPad

 Для Android

АКЦИЯ!

Бесплатный доступ