IEEE C57.139 Guide for Dissolved Gas Analysis in Transformer Load Tap Changers
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D2112 REV A Standard Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel
- 29
- ASTM D4895 Standard Specification for Polytetrafluoroethylene (PTFE) Resin Produced From Dispersion
- ASTM D2902 Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation
- ASTM D3636 REV A Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials
- ASTM D2902 Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation
- ASTM D2902 Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation
- ASTM D3636 REV A Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials
- ASTM D3636 REV A Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials
- ASTM D3394 Standard Test Methods for Sampling and Testing Electrical Insulating Board
- ASTM D3455 Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin
- ASTM D924 Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids
- IEEE C57.106 Guide for Acceptance and Maintenance of Insulating Mineral Oil in Electrical Equipment
- Картотека зарубежных и международных стандартов
The Institute of Electrical and Electronics Engineers, Inc.
Guide for Dissolved Gas Analysis in Transformer Load Tap Changers
N C57.139
Annotation
This guide discusses and recommends methods of testing and evaluating dissolved gases in mineral based transformer oils found in load tap changers (LTCs). General types of LTC mechanisms, breathing configurations, and electrical design will be included for evaluation criteria in determining when mechanical damage or failure has occurred. Dissolved gas analysis (DGA) of the oil in the LTC is required. This guide is not manufacturer specific, rather category specific.
Purpose
The purpose of this guide is to assist the responsible parties who are in charge of the operation and maintenance decisions in evaluating the condition of an LTC without the need to de-energize the transformer to inspect the LTC in question. Additionally, repairs to the LTC can be made in a timely fashion based on accurate interpretation of the gas analysis, minimizing premature repairs or post failure rebuilds.
Автоматический перевод:
Гид для анализа растворенного газа в переключателях сигнала груза трансформатора
Этот гид обсуждает и рекомендует методы испытания, и оценка растворенных газов в минерале базировала трансформаторные масла, найденные в преобразователях сигнала загрузки (LTCs). Общие типы механизмов LTC, вдыхая конфигурации и электрический дизайн будут включены для критериев оценки в определении, когда механический ущерб или отказ произойдут. Анализ растворенного газа (DGA) нефти в LTC требуется. Этот гид не является определенным производителем, скорее определенная категория.