IEEE 400.4 Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- CSA CAN/CSA-C22.2 NO. 61010-031-07 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 19
- CSA CAN/CSA-C22.2 NO. 61010-031-07 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- 19.080
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- 13
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- 13.260
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- 29
- IEC 60529 CORR 3 Degrees of Protection Provided by Enclosures (IP Code) - Edition 2.1
- CSA CAN/CSA-C22.2 NO. 61010-031-07 AMD 1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test - First Edition
- Картотека зарубежных и международных стандартов
The Institute of Electrical and Electronics Engineers, Inc.
Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
N 400.4
Annotation
This guide presents the practices and procedures for testing and diagnosis of shielded power cable systems rated 5 kV and above using DAC voltages. It applies to all types of power cable systems that are intended for the transmission or distribution of electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.
Purpose
The purpose of this guide is to provide uniform practices and procedures for performing (DAC) voltage off-line tests on installed shielded power cable systems in the field and to provide guidelines for evaluation of the test results. As at present certain test parameters and procedures require further study and clarification, this guide provides a starting point that can be grown and improved with time as more experience is gathered from the field and analyzed.
Автоматический перевод:
Гид для Полевых испытаний Экранированных Систем Силового кабеля Номинальные 5 кВ и Выше с Напряжением Заглушенного переменного тока (DAC)
Это руководство представляет методы и процедуры для тестирования, и диагноз экранированных систем силового кабеля оценил 5 кВ и выше использования напряжений DAC. Это относится ко всем типам систем силового кабеля, которые предназначаются для передачи или распределения электроэнергии. Сведенные в таблицу тестовые уровни предполагают, что кабельные системы имеют эффективно основанную нейтральную систему или основанный металлический щит.