ICEA S-85-625-2011 TELECOMMUNICATIONS CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS - Fifth Edition
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM B983 REV A Standard Specification for Precipitation Hardened or Cold Worked, Seamless Nickel Alloy Pipe and Tube
- 23
- ASME B31.5 Refrigeration Piping and Heat Transfer Components
- ASTM B43 Standard Specification for Seamless Red Brass Pipe, Standard Sizes
- ASTM B43 Standard Specification for Seamless Red Brass Pipe, Standard Sizes
- ASTM B687 Standard Specification for Brass, Copper, and Chromium-Plated Pipe Nipples
- ASTM B706 Standard Specification for Seamless Copper Alloy (UNS No. C69100) Pipe and Tube
- ASTM B193 Standard Test Method for Resistivity of Electrical Conductor Materials
- ASTM B624 Standard Specification for High-Strength, High-Conductivity Copper-Alloy Wire for Electronic Application
- ASTM E8/E8M REV A Standard Test Methods for Tension Testing of Metallic Materials
- Картотека зарубежных и международных стандартов
Insulated Cable Engineers Association Inc.
TELECOMMUNICATIONS CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS - Fifth Edition
N S-85-625-2011
Annotation
This Standard covers mechanical and electrical requirements for aircore, polyolefin insulated, copper conductor telecommunications cable. It provides alternative choices for type of insulation, core assembly, color code, sheath design (shielding materials, single or double jackets, and jacket thickness), and screened or non-screened core.
PURPOSE: The purpose of this Standard is to establish generic technical requirements that may be referenced by individual telecommunications cable specifications covering products intended for normal outside plant use. The parameters covered provide material, construction, and performance requirements that are applicable to aircore, polyolefin insulated and jacketed cables of all pair counts, including a variety of shield and jacket combinations and optional compartmental screening.
Because this Standard does not cover all details of individual cable design, it cannot be used as a single document for procurement of product. It is intended to be used in conjunction with an individual product specification that provides complete design details for the specific cable type and designates the applicable performance requirements. Such individual cable specifications may be prepared either by the user or the manufacturer. The specification designated for procurement is at the option of the user.
Автоматический перевод:
TELECOMMUNICATIONS CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS - пятый выпуск
Этот Стандарт удовлетворяет механические и электрические требования для aircore, изолированный полиолефин, телекоммуникационный кабель медного проводника. Это обеспечивает альтернативный выбор для типа изоляции, базового блока, цветового кода, дизайн оболочки (экранирующий материалы, единственные или двойные конверты и толщину конверта), и экранированное или неэкранированное ядро.