ASTM D7094 Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Данный раздел/документ содержится в продуктах:
- Техэксперт: Машиностроительный комплекс
- Картотека зарубежных и международных стандартов
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87.060
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- 87.060.99
- ASTM D2373 Standard Test Method for Determination of Cobalt in Paint Driers by EDTA Method
- ASTM D2374 Standard Test Method for Lead in Paint Driers by EDTA Method
- ASTM D600 Standard Specification for Liquid Paint Driers
- ASTM D211 Standard Specification for Chrome Yellow and Chrome Orange Pigments
- ASTM D126 Standard Test Methods for Analysis of Yellow, Orange, and Green Pigments Containing Lead Chromate and Chromium Oxide Green
- ASTM D4814 REV A Standard Specification for Automotive Spark-Ignition Engine Fuel
- ASTM D7220 Standard Test Method for Sulfur in Automotive, Heating, and Jet Fuels by Monochromatic Energy Dispersive X-ray Fluorescence Spectrometry
- ASTM D396 REV C Standard Specification for Fuel Oils
- Картотека зарубежных и международных стандартов
ASTM International
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
N D7094
Annotation
This test method covers the determination of the flash point of fuels, lube oils, solvents and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5 °C per minute.
Apparatus requiring a specimen size of 1 mL, cup size of 4 mL, and a heating rate of 5.5 °C per minute must be run according to Test Method D6450.
This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method.
NOTE 1—Flash point values are not a constant physical chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can, therefore, only be defined in terms of a standard test method and no general valid correlation can be guaranteed between results obtained by different test methods or where different test apparatus is specified.
This test method utilizes a closed but unsealed cup with air injected into the test chamber.
This test method is suitable for testing samples with a flash point from 35 °C to 225 °C.
NOTE 2—Flash point determinations below 35 °C and above 225 °C may be performed; however, the precision has not been determined below and above these temperatures.
If the user’s specification requires a defined flash point method other than this method, neither this method nor any other test method should be substituted for the prescribed test method without obtaining comparative data and an agreement from the specifier.